# §64.11. Design of MPTs.


An MPT must be designed—

- (a) In accordance with Section VIII of the ASME BPVC (incorporated by reference; see [§ 64.2](/cfr/46/64.2.md)) and this subpart;
- (b) With a maximum gross weight of 55,000 pounds;
- (c) To hold a liquid cargo that has a vapor pressure of 43 pounds per square inch absolute (psia) or less at a temperature of 122 °F;
- (d) With a minimum service temperature of 0 °F or higher;
- (e) With a maximum allowable working pressure of not less than 20 pounds per square inch gauge (psig) but not more than 48 psig; and
- (f) **To withstand dynamic loading conditions applied simultaneously.**