# §62.35-10. Flooding safety.

- (a) **Automatic bilge pumps must—**
  - (1) Be provided with bilge high level alarms that annunciate in the machinery spaces and at a manned control location and are independent of the pump controls;
  - (2) Be monitored to detect excessive operation in a specified time period; and
  - (3) **Meet all applicable pollution control requirements.**
- (b) Remote controls for flooding safety equipment must remain functional under flooding conditions.
- (c) Remote bilge level sensors, where provided, must be located to detect flooding at an early stage and to provide redundant coverage.