# §58.50-1. General requirements.

- (a) **The regulations in this subpart contain requirements for independent fuel tanks.**
- (b) Passenger vessels exceeding 100 gross tons constructed on or after July 1, 1935, and emergency systems for all ships, must use fuel that has a flashpoint exceeding 110 °F for internal combustion engine units. Such vessels must carry a sufficient quantity of fuel to supply the emergency electrical system. Refer to [§ 112.05-5](/cfr/46/112.05-5.md) of subchapter J, of this chapter.
- (c) An outage of 2 percent must be provided on all fuel tanks containing petroleum products.

## Notes

### Source

Source: USCG-2020-0634, 89 FR 50179, June 12, 2024, unless otherwise noted.

### Authority

Authority: 43 U.S.C. 1333; 46 U.S.C. 3306, 3703; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; DHS Delegation No. 00170.1, Revision No. 01.4.

### Source

Source: CGFR 68-82, 33 FR 18878, Dec. 18, 1968, unless otherwise noted.