---
kind: "section"
citation: "46 C.F.R. § 56.97-5"
title: "46"
number: "56.97-5"
heading: "Pressure testing of nonstandard piping system components."
url: "https://uscodex.org/cfr/46/56.97-5"
---

# §56.97-5. Pressure testing of nonstandard piping system components.

- (a) All nonstandard piping system components such as welded valves and fittings, nonstandard fittings, manifolds, seacocks, and other appurtenances must be hydrostatically tested to twice the rated pressure stamped thereon, except that no component should be tested at a pressure causing stresses in excess of 90 percent of its yield strength.
- (b) Items for which an accepted standard appears in table 2 to [§ 56.60-1](/cfr/46/56.60-1.md) need not be tested as described in [paragraph (a)](#a) of this section, but need only meet the test required in the applicable standard.

## Notes

### Amendments

[CGFR 68-82, 33 FR 18843, Dec. 18, 1968, as amended by CGD 77-140, 54 FR 40615, Oct. 2, 1989]

### Source

Source: CGFR 68-82, 33 FR 18843, Dec. 18, 1968, as amended by USCG-2020-0634, 89 FR 50158, June 12, 2024, unless otherwise noted.

### Authority

Authority: 33 U.S.C. 1321(j), 1509; 43 U.S.C. 1333; 46 U.S.C. 3306, 3703; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; E.O. 12777, 56 FR 54757, 3 CFR, 1991 Comp., p. 351; DHS Delegation No. 00170.1, Revision No. 01.4.

### Source

Source: CGFR 68-82, 33 FR 18843, Dec. 18, 1968, unless otherwise noted.

### Amendments

[CGFR 68-82, 33 FR 18843, Dec. 18, 1968, as amended by CGD 77-140, 54 FR 40615, Oct. 2, 1989]
