# §182.530. Bilge high level alarms.

- (a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:
  - (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;
  - (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and
  - (3) **A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.**
- (b) Vessels constructed of wood must, in addition to [paragraph (a)](#a), provide bilge level alarms in all watertight compartments except small buoyancy chambers.
- (c) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.