# §174.195. Bulkheads in machinery spaces.

- (a) The bulkhead in each machinery space of each OSV must be watertight to the bulkhead deck.
- (b) **Each penetration of, and each opening in, a bulkhead in a machinery space must—**
  - (1) Be kept as high and as far inboard as practicable; and
  - (2) Except as provided by [§ 174.210](/cfr/46/174.210.md) of this subpart and by [paragraph (c)](#c) of this section, have means to make it watertight.
- (c) No penetration of a bulkhead in a machinery space by a ventilation duct need have means to make the bulkhead watertight if—
  - (1) Every part of the duct is at least 760 millimeter (30 inches) from the side of the OSV; and
  - (2) **The duct is continuously watertight from the penetration to the main deck.**
- (d) Each penetration of a bulkhead in a machinery space by piping must meet the design requirements for material and pressure in subchapter F of this chapter.