# §169.681. Disconnect switches and devices.

- (a) Externally operable switches or circuit breakers must be provided for motor and controller circuits and must open all ungrounded conductors of the circuit.
- (b) If the disconnect means is not within sight of the equipment that the circuit supplies, means must be provided for locking the disconnect device in the “open” position.
- (c) For circuits protected by fuses, the disconnect switch required for fuses in [§ 169.683(b)](/cfr/46/169.683.md?p=b) of this chapter is adequate for disconnecting the circuit from the supply.
- (d) The disconnect means may be in the same enclosure with motor controllers.
- (e) Disconnect means must be provided to open all conductors of generator and shore power cables.