# §169.607. Keel cooler installations.

- (a) Except as provided in this section, keel cooler installations must meet the requirements of [§ 56.50-96](/cfr/46/56.50-96.md) of this chapter.
- (b) Approved metallic flexible connections may be located below the deepest load waterline if the system is a closed loop below the waterline and its vent is located above the waterline.
- (c) Fillet welds may be used in the attachment of channels and half round pipe sections to the bottom of the vessel.
- (d) Short lengths of approved nonmetallic flexible hose may be used at machinery connections fixed by hose clamps provided that—
  - (1) The clamps are of a corrosion resistant material;
  - (2) The clamps do not depend on spring tension for their holding power; and
  - (3) Two clamps are used on each end of the hose or one hose clamp is used and the pipe ends are expanded or beaded to provide a positive stop against hose slippage.