# §154.703. Methane (LNG).


Unless a cargo tank carrying methane (LNG) can withstand the pressure build up due to boil-off for 21 days, the pressure in the cargo tank must be maintained below the set pressure of the safety relief valve for at least 21 days by:

- (a) A refrigeration system that meets [§ 154.702](/cfr/46/154.702.md);
- (b) **A waste heat or catalytic furnace that burns boil-off gas, and—**
  - (1) Maintains the stack exhaust temperature below 535 °C (995 °F);
  - (2) Exhibits no visible flame; and
  - (3) Is specially approved by the Commandant (CG-OES);
- (c) Boilers, inert gas generators, and combustion engines in the main propelling machinery space that use boil-off gas as fuel; or
- (d) Equipment for services, other than those under [paragraph (c)](#c) of this section, that use boil-off gas as fuel and that are located:
  - (1) In the main propelling machinery space; or
  - (2) a space specially approved by the Commandant (CG-OES).