# §154.530. Valves: Cargo tank MARVS 69 kPa gauge (10 psig) or lower.

- (a) Except those connections for tank safety relief valves and for liquid level gauging devices other than those under §§ [154.536](/cfr/46/154.536.md) and [154.1310](/cfr/46/154.1310.md), liquid and vapor connections on a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have shut-off valves that—
  - (1) Are located as close to the tank as practical;
  - (2) Are capable of local manual operation; and
  - (3) **May be remotely controlled.**
- (b) The cargo piping system for a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have at least one remotely controlled quick-closing shut-off valve for closing liquid and vapor piping between vessel and shore that meets §§ [154.540](/cfr/46/154.540.md) and [154.544](/cfr/46/154.544.md).