# §154.1330. Liquid level alarm system: Independent tank type C.


Independent tanks type C need not have the high liquid level alarm system under [§ 154.1325](/cfr/46/154.1325.md) if:

- (a) **The tank volume is less than 200 m 3 (7,060 ft.** 3); or
- (b) The tank can withstand the maximum possible pressure during loading, that pressure is below the relief valve setting, and overflow of the tank cannot occur.