# §154.1145. Dry chemical supply.

- (a) **A vessel with a cargo carrying capacity less that 1000 m 3 (35,300 ft.** 3) must have at least one self-contained dry chemical storage unit for the cargo area with an independent inert gas pressurizing source adjacent to each unit.
- (b) **A vessel with a cargo carrying capacity of 1000 m 3 (35,300 ft.** 3) or more must have at least two self-contained dry chemical storage units for the cargo area with an independent inert gas pressurizing source adjacent to each unit.
- (c) A vessel with bow and stern loading and discharge areas must have at least one self-contained dry chemical storage unit with an independent inert gas pressurizing source adjacent to the unit for each area.
- (d) Each dry chemical storage unit and associated piping must be designed for:
  - (1) Sequential discharge of each hose line and each monitor for 45 seconds; and
  - (2) **Simultaneous discharge of all hose lines and monitors for 45 seconds.**
- (e) Each fully charged dry chemical storage unit must have the greater of the following:
  - (1) Enough dry chemical to provide for sequential discharge of each attached hose and monitor for 45 seconds.
  - (2) Enough dry chemical to provide for simultaneous discharge of all attached hoses and monitors for 45 seconds.