kind: "section"
citation: "46 C.F.R. § 132.330"
title: "46"
number: "132.330"
heading: "Fire monitors."
url: "https://uscodex.org/cfr/46/132.330"
---

# §132.330. Fire monitors.

- (a) Each fire monitor of the fire main system must be fitted with a shut-off valve at the monitor and at the connection to the fire main discharge manifold required by [§ 132.120(h)](/cfr/46/132.120.md?p=h) of this part.
- (b) Fire monitor piping must comply with [§ 132.110](/cfr/46/132.110.md) of this part.
- (c) Each fire monitor must be protected against over-pressure.

## Notes

### Authority

Authority: 46 U.S.C. 3306, 3307; sec. 617, Pub. L. 111-281, 124 Stat. 2905; DHS Delegation 00170.1, Revision No. 01.4.

### Source

Source: CGD 82-004 and CGD 86-074, 62 FR 49348, Sept. 19, 1997, unless otherwise noted.