# §131.570. Quarterly inspections.

- (a) Each apparatus that controls a lifeboat winch, including motor controllers, emergency switches, master switches, and limit switches, must be inspected once each 3 months.
- (b) The inspection must involve the removal of drain plugs and the opening of drain valves to ensure that enclosures are free of water.
- (c) The date of the inspection required by this section and the condition of the equipment must be entered in the vessel's logbook.