kind: "section"
citation: "46 C.F.R. § 130.460"
title: "46"
number: "130.460"
heading: "Placement of machinery alarms."
url: "https://uscodex.org/cfr/46/130.460"
---

# §130.460. Placement of machinery alarms.

- (a) Visible and audible alarms must be installed at the pilothouse to indicate the following:
  - (1) **Loss of power for propulsion control.**
  - (2) **Loss of power to the steering motor or for control of the main steering gear.**
  - (3) **Engine-room fire.**
  - (4) **High bilge-level.**
  - (5) **Low lube-oil pressure for each main propulsion engine and each prime mover of a generator.**
  - (6) **For each main propulsion engine and each prime mover of a generator—**
    - (i) High lube-oil temperature; and
    - (ii) **High jacket-water temperature.**
  - (7) **For each reduction gear and each turbocharger with a pressurized oil system—**
    - (i) Low lube-oil pressure; and
    - (ii) **High lube-oil temperature.**
  - (8) **Loss of normal power for the alarms listed in paragraphs (a)(1) through (a)(7) of this section.**
- (b) Sensors for the high-bilge-level alarm required by [paragraph (a)(4)](#a-4) of this section must be installed in—
  - (1) Each space below the deepest load waterline that contains pumps, motors, or electrical equipment; and
  - (2) **The compartment that contains the rudder post.**
- (c) Centralized displays must be installed in the machinery spaces to allow rapid evaluation of each problem detected by the alarms required by [paragraph (a)](#a) of this section. Equipment-mounted gauges or meters are acceptable for this purpose, if they are grouped at a central site.

## Notes

### Authority

Authority: 46 U.S.C. 3306; Department of Homeland Security Delegation No. 0170.1. Sections 130.140 and 130.400 also issued under sec. 617, Pub. L. 111-281, 124 Stat. 2905.

### Source

Source: CGD 82-004 and CGD 86-074, 62 FR 49337, Sept. 19, 1997, unless otherwise noted.