# §129.370. Equipment grounding.

- (a) On a metallic vessel each metallic enclosure and frame of electrical equipment must be permanently grounded to the hull. On a nonmetallic vessel each enclosure and frame of electrical equipment must be bonded to each other and to a common ground by a conductor not normally carrying current.
- (b) Each metallic case of instruments must be grounded. So must each secondary winding of instrument transformers.
- (c) Each equipment grounding conductor must be sized to comply with [section 250-95](/cfr/46/250-95.md) of NEC (NFPA 70).
- (d) Each nonmetallic mast and topmast must have a lightning-ground conductor.