# §127.430. Visibility from pilothouse.

- (a) Windows and other openings at the pilothouse must be of sufficient size and properly located to provide adequate view for safe operation in any condition.
- (b) Glass or other glazing material used in windows at the pilothouse must have a light transmission of at least 70 percent according to Test 2 of ANSI Z26.1, “Code for Safety Glazing Materials for Glazing Motor Vehicles Operating on Land Highways,” and must comply with Test 15 of ANSI Z26.1 for Class I Optical Deviation.

## Notes

### Authority

Authority: 46 U.S.C. 3306; sec. 617, Pub. L. 111-281, 124 Stat. 2905; Department of Homeland Security Delegation No. 0170.1.

### Source