# §118.300. Fire pumps.

- (a) A self priming, power driven fire pump must be installed on each vessel.
- (b) On a vessel without overnight accommodations, or with overnight accommodations for not more than 49 passengers, the fire pump must be capable of delivering a single hose stream from the highest hydrant, through the hose and nozzle required by [§ 118.320](/cfr/46/118.320.md) of this part, at a pitot tube pressure of 345 kPa (50 psi).
- (c) On a vessel carrying more than 600 passengers or with overnight accommodations for more than 49 passengers, the fire pump must meet [§ 76.10-5](/cfr/46/76.10-5.md) of this chapter.
- (d) A fire pump may be driven by a propulsion engine. A fire pump must be permanently connected to the fire main and may be connected to the bilge system to meet the requirements of [§ 119.520](/cfr/46/119.520.md) of this subchapter.
- (e) A fire pump must be capable of both remote operation from the operating station and local operation at the pump.