# §113.43-5. Power supply.


Each steering failure alarm system must be supplied by a circuit that:

- (a) Is independent of other steering gear system and steering alarm circuits;
- (b) Is fed from the final emergency power source through the emergency distribution panel in the wheelhouse, if installed; and
- (c) Has no overcurrent protection except short-circuit protection by an instantaneous fuse or circuit breaker rated or set at 400 to 500 percent of:
  - (1) The current-carrying capacity of the smallest alarm system interconnecting conductors; or
  - (2) **The normal load of the system.**