# §111.97-7. Distribution.

- (a) Each distribution panelboard for a watertight door system must be above the uppermost continuous deck and must have means for locking.
- (b) Each feeder supplying a watertight door operating system must be above the uppermost continuous deck.
- (c) Each watertight door operating system must have a separate branch circuit.