# §111.79-1. Receptacle outlets; general.

- (a) There must be a sufficient number of receptacle outlets in the crew accommodations for an adequate level of habitability.
- (b) There must be a sufficient number of receptacle outlets throughout the machinery space so that any location can be reached by a portable power cord having a length not greater than 24 meters (75 feet).
- (c) Each receptacle outlet must be compatible with the voltage and current of the circuit in which it is installed.
- (d) Each receptacle outlet must be suitable for the environment in which it is installed and constructed to the appropriate NEMA or IEC protection standard as referenced in [§ 111.01-9](/cfr/46/111.01-9.md). Special attention must be given to outlets in hazardous locations.
- (e) A receptacle outlet must not have any exposed live parts with the plug opening uncovered.