# §108.477. Fire hydrants.

- (a) If a fixed foam extinguishing system has outlets in a main machinery space, at least 2 fire hydrants, in addition to the fire hydrants required by [§ 108.423](/cfr/46/108.423.md) of this subpart, must be installed outside the entrances to the space with each at a separate entrance.
- (b) Each hydrant must have enough hose to spray any part of the space.
- (c) Each hydrant must have a combination nozzle and applicator.