# §108.181. Ventilation for enclosed spaces.

- (a) Each enclosed space must be vented or ventilated.
- (b) There must be a means to close each vent or ventilating system.
- (c) Each fan in a ventilating system must have remote controls installed in accordance with [part 111](/cfr/46/part111.md), [subpart 111.103](/cfr/46/subpart111.103.md), of this chapter.
- (d) There must be a means to close each doorway, ventilator, and annular space around each funnel or other opening to machinery, stowage, or working spaces. The means must be located outside the space.
- (e) Each intake in a ventilating system must be located so as to prevent, as far as practicable, the intake of noxious fumes.