kind: "section"
citation: "43 C.F.R. § 3175.93"
title: "43"
number: "3175.93"
heading: "Integration statements."
url: "https://uscodex.org/cfr/43/3175.93"
---

# §3175.93. Integration statements.


An unedited integration statement must be retained and made available to the BLM upon request. The integration statement must contain the following information:

- (a) The information required in [§ 3170.7(g)](/cfr/43/3170.7.md?p=g) of this part;
- (b) The name of the company performing the integration;
- (c) The month and year for which the integration statement applies;
- (d) Meter-tube inside diameter (inches);
- (e) **The following primary device information, as applicable—**
- (i) Orifice bore diameter (inches); or
- (ii) Beta or area ratio, discharge coefficient, and other information necessary to calculate the flow rate;
- (f) Relative density (specific gravity);
- (g) CO2 content (mole percent);
- (h) N2 content (mole percent);
- (i) Heating value calculated under [§ 3175.125](/cfr/43/3175.125.md) (Btu/standard cubic feet);
- (j) Atmospheric pressure or elevation at the FMP;
- (k) Pressure base;
- (l) Temperature base;
- (m) Static-pressure tap location (upstream or downstream);
- (n) Chart rotation (hours or days);
- (o) Differential-pressure bellows range (inches of water);
- (p) Static-pressure element range (psi); and
- (q) **For each chart or day integrated—**
- (i) The time and date on and time and date off;
- (ii) Average differential pressure (inches of water);
- (iii) Average static pressure;
- (iv) Static-pressure units of measure (psia or psig);
- (v) Average temperature ( °F);
- (vi) Integrator counts or extension;
- (vii) Hours of flow; and
- (viii) **Volume (Mcf).**

## Notes

### Source

Source: 81 FR 81609, Nov. 17, 2016, unless otherwise noted.

### Authority

Authority: 25 U.S.C. 396d and 2107; 30 U.S.C. 189, 306, 359, and 1751; and 43 U.S.C. 1732(b), 1733, and 1740.

### Source

Source: 81 FR 81421, Nov. 17, 2016, unless otherwise noted.