# §3175.111. General sampling requirements.

- (a) Samples must be taken by one of the following methods:
  - (1) Spot sampling under [§§ 3175.113 through 3175.115](/cfr/43/3175.113..3175.115.md);
  - (2) Flow-proportional composite sampling under [§ 3175.116](/cfr/43/3175.116.md); or
  - (3) On-line gas chromatograph under [§ 3175.117](/cfr/43/3175.117.md).
- (b) At all times during the sampling process, the minimum temperature of all gas sampling components must be the lesser of:
  - (1) The flowing temperature of the gas measured at the time of sampling; or
  - (2) 30 °F above the calculated hydrocarbon dew point of the gas.