# §84.90. Breathing resistance test; inhalation.

- (a) Resistance to inhalation airflow will be measured in the facepiece or mouthpiece while the apparatus is operated by a breathing machine as described in [§ 84.88](/cfr/42/84.88.md).
- (b) The inhalation resistance of open-circuit apparatus shall not exceed 32 mm. (1.25 inch) water-column height (at a flow rate of 120 liters per minute).
- (c) The inhalation resistance of closed-circuit apparatus shall not exceed the difference between exhalation resistance ([§ 84.91(e)](/cfr/42/84.91.md?p=e)) and 10 cm. (4 inches) water-column height.