kind: "section"
citation: "42 C.F.R. § 84.255"
title: "42"
number: "84.255"
heading: "Requirements for end-of-service-life indicator."
url: "https://uscodex.org/cfr/42/84.255"
---

# §84.255. Requirements for end-of-service-life indicator.

- (a) Each canister or cartridge submitted for testing and approval in accordance with §§ [84.252](/cfr/42/84.252.md), [84.253](/cfr/42/84.253.md), and [84.254](/cfr/42/84.254.md) shall be equipped with a canister or cartridge end-of-service-life indicator which shows a satisfactory indicator change or other obvious warning before 1 ppm vinyl chloride penetration occurs. The indicator shall show such change or afford such warning at 80 ±10 percent of the total service life to 1 ppm leakage, as determined by continuing each test described in §§ [84.252(b)](/cfr/42/84.252.md?p=b), [84.253(b)](/cfr/42/84.253.md?p=b), and [84.254(b)](/cfr/42/84.254.md?p=b) until a 1 ppm leakage of vinyl chloride occurs.
- (b) The applicant shall provide sufficient pretest data to verify the performance of the end-of-service-life indicator required in [paragraph (a)](#a) of this section.

## Notes

### Authority

Authority: 29 U.S.C. 651 et seq.; 30 U.S.C. 3, 5, 7, 811, 842(h), 844.

### Source

Source: 60 FR 30355, June 8, 1995, unless otherwise noted.