kind: "section"
citation: "40 C.F.R. § 63.8234"
title: "40"
number: "63.8234"
heading: "What equations and procedures must I use for the initial compliance demonstration?"
url: "https://uscodex.org/cfr/40/63.8234"
---

# §63.8234. What equations and procedures must I use for the initial compliance demonstration?

- (a) **By-product hydrogen streams and end box ventilation system vents.** You must determine the total grams of mercury per Megagram of chlorine production (g Hg/Mg Cl2) of chlorine produced from all by-product hydrogen streams and all end box ventilation system vents, if applicable, at a mercury cell chlor-alkali production facility, and you must follow the procedures in [paragraphs (a)(1) through (6)](#a-1..a-6) of this section.
  - (1) Determine the mercury emission rate for each test run in grams per day for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, from Method 101, 101A, or 102 ([40 CFR part 61](/cfr/40/part61.md), appendix A).
  - (2) Calculate the average measured electric current through the operating mercury cells during each test run for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 1 of this section as follows:
  - (3) Calculate the amount of chlorine produced during each test run for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 2 of this section as follows:
  - (4) Calculate the mercury emission rate in grams of mercury per megagram of chlorine produced for each test run for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 3 of this section as follows:
  - (5) Calculate the average mercury emission rate for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 4 of this section as follows:
  - (6) Calculate the total mercury emission rate from all by-product hydrogen streams and all end box ventilation system vents, if applicable, at the mercury cell chlor-alkali production facility using Equation 5 of this section as follows:
- (b) **Mercury thermal recovery vents.** You must determine the milligrams of mercury per dscm exhaust discharged from mercury thermal recovery unit vents, using the procedures in paragraphs [(b)(1)](#b-1) and [(2)](#b-2) of this section.
  - (1) Calculate the concentration of mercury in milligrams of mercury per dscm of exhaust for each test run for each mercury thermal recovery unit vent using Equation 6 of this section as follows:
  - (2) Calculate the average concentration of mercury in each mercury thermal recovery unit vent exhaust using Equation 7 of this section as follows:

## Notes

### Source

Source: 68 FR 70928, Dec. 19, 2003, unless otherwise noted.

### Authority

Authority: 42 U.S.C. 7401 et seq.

### Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.