# §62.14670. How do I demonstrate continuous compliance with the emission limitations and the operating limits?

- (a) You must conduct an annual performance test for particulate matter, hydrogen chloride, and opacity for each CISWI unit as required under [40 CFR 60.8](/cfr/40/60.8.md) to determine compliance with the emission limitations. The annual performance test must be conducted using the test methods listed in table 1 of this subpart and the procedures in [§ 62.14650](/cfr/40/62.14650.md).
- (b) You must continuously monitor the operating parameters specified in [§ 62.14635](/cfr/40/62.14635.md) or established under [§ 62.14640](/cfr/40/62.14640.md). Operation above the established maximum or below the established minimum operating limits constitutes a deviation from the established operating limits. Three-hour rolling average values are used to determine compliance (except for baghouse leak detection system alarms) unless a different averaging period is established under [§ 62.14640](/cfr/40/62.14640.md). Operating limits do not apply during performance tests.
- (c) You must only burn the same types of waste used to establish operating limits during the performance test.