# §60.6010. What is the minimum amount of monitoring data I must collect with my continuous parameter monitoring systems?

- (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for all the following three parameters:
  - (1) **Load level of the municipal waste combustor.**
  - (2) **Temperature of the flue gases at the inlet of your particulate matter control device.**
  - (3) **Carbon feed rate if activated carbon is used to control dioxins/furans or mercury emissions.**
- (b) **Obtain at least two data points per hour in order to calculate a valid 1-hour arithmetic average.**
- (c) Obtain valid 1-hour arithmetic averages for at least 75 percent of the operating hours per day for 90 percent of the operating days per calendar quarter.