kind: "section"
citation: "40 C.F.R. § 60.482-5"
title: "40"
number: "60.482-5"
heading: "Standards: Sampling connection systems."
url: "https://uscodex.org/cfr/40/60.482-5"
---

# §60.482-5. Standards: Sampling connection systems.

- (a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed-vent system, except as provided in [§ 60.482-1(c)](/cfr/40/60.482-1.md?p=c) and [paragraph (c)](#c) of this section.
- (b) Each closed-purge, closed-loop, or closed-vent system as required in [paragraph (a)](#a) of this section shall comply with the requirements specified in [paragraphs (b)(1) through (4)](#b-1..b-4) of this section.
  - (1) **Gases displaced during filling of the sample container are not required to be collected or captured.**
  - (2) Containers that are part of a closed-purge system must be covered or closed when not being filled or emptied.
  - (3) Gases remaining in the tubing or piping between the closed-purge system valve(s) and sample container valve(s) after the valves are closed and the sample container is disconnected are not required to be collected or captured.
  - (4) Each closed-purge, closed-loop, or closed-vent system shall be designed and operated to meet requirements in either paragraph [(b)(4)(i)](#b-4-i), [(ii)](#b-4-ii), [(iii)](#b-4-iii), or [(iv)](#b-4-iv) of this section.
    - (i) **Return the purged process fluid directly to the process line.**
    - (ii) **Collect and recycle the purged process fluid to a process.**
    - (iii) Capture and transport all the purged process fluid to a control device that complies with the requirements of [§ 60.482-10](/cfr/40/60.482-10.md).
    - (iv) **Collect, store, and transport the purged process fluid to any of the following systems or facilities—**
      - (A) A waste management unit as defined in [§ 63.111](/cfr/40/63.111.md), if the waste management unit is subject to and operated in compliance with the provisions of [40 CFR part 63](/cfr/40/part63.md), [subpart G](/cfr/40/subpartG.md), applicable to Group 1 wastewater streams;
      - (B) A treatment, storage, or disposal facility subject to regulation under 40 CFR part [262](/cfr/40/part262.md), [264](/cfr/40/part264.md), 265, or 266;
      - (C) A facility permitted, licensed, or registered by a state to manage municipal or industrial solid waste, if the process fluids are not hazardous waste as defined in [40 CFR part 261](/cfr/40/part261.md);
      - (D) A waste management unit subject to and operated in compliance with the treatment requirements of [§ 61.348(a)](/cfr/40/61.348.md?p=a), provided all waste management units that collect, store, or transport the purged process fluid to the treatment unit are subject to and operated in compliance with the management requirements of [§§ 61.343 through 61.347](/cfr/40/61.343..61.347.md); or
      - (E) A device used to burn off-specification used oil for energy recovery in accordance with [40 CFR part 279](/cfr/40/part279.md), [subpart G](/cfr/40/subpartG.md), provided the purged process fluid is not hazardous waste as defined in [40 CFR part 261](/cfr/40/part261.md).
- (c) In situ sampling systems and sampling systems without purges are exempt from the requirements of paragraphs [(a)](#a) and [(b)](#b) of this section.

## Notes

### Amendments

[60 FR 43258, Aug. 18, 1995, as amended at 65 FR 61762, Oct. 17, 2000; 65 FR 78277, Dec. 14, 2000; 72 FR 64881, Nov. 16, 2007]

### Source

Source: 48 FR 48335, Oct. 18, 1983, unless otherwise noted.

### Authority

Authority: 42 U.S.C. 7401 et seq.

### Source

Source: 36 FR 24877, Dec. 23, 1971, unless otherwise noted.

### Amendments

[60 FR 43258, Aug. 18, 1995, as amended at 65 FR 61762, Oct. 17, 2000; 65 FR 78277, Dec. 14, 2000; 72 FR 64881, Nov. 16, 2007]