kind: "section"
citation: "40 C.F.R. § 60.43"
title: "40"
number: "60.43"
heading: "Standard for sulfur dioxide (SO 2 )."
url: "https://uscodex.org/cfr/40/60.43"
---

# §60.43. Standard for sulfur dioxide (SO 2 ).

- (a) Except as provided under [paragraph (d)](#d) of this section, on and after the date on which the performance test required to be conducted by [§ 60.8](/cfr/40/60.8.md) is completed, no owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere from any affected facility any gases that contain SO2 in excess of:
  - (1) 340 ng/J heat input (0.80 lb/MMBtu) derived from liquid fossil fuel or liquid fossil fuel and wood residue.
  - (2) 520 ng/J heat input (1.2 lb/MMBtu) derived from solid fossil fuel or solid fossil fuel and wood residue, except as provided in [paragraph (e)](#e) of this section.
- (b) Except as provided under [paragraph (d)](#d) of this section, when different fossil fuels are burned simultaneously in any combination, the applicable standard (in ng/J) shall be determined by proration using the following formula:
- (c) Compliance shall be based on the total heat input from all fossil fuels burned, including gaseous fuels.
- (d) As an alternate to meeting the requirements of paragraphs [(a)](#a) and [(b)](#b) of this section, an owner or operator can petition the Administrator (in writing) to comply with [§ 60.43Da(i)(3)](/cfr/40/60.43Da.md?p=i-3) of [subpart Da](/cfr/40/subpartDa.md) of this part or comply with [§ 60.42b(k)(4)](/cfr/40/60.42b.md?p=k-4) of [subpart Db](/cfr/40/subpartDb.md) of this part, as applicable to the affected source. If the Administrator grants the petition, the source will from then on (unless the unit is modified or reconstructed in the future) have to comply with the requirements in [§ 60.43Da(i)(3)](/cfr/40/60.43Da.md?p=i-3) of [subpart Da](/cfr/40/subpartDa.md) of this part or [§ 60.42b(k)(4)](/cfr/40/60.42b.md?p=k-4) of [subpart Db](/cfr/40/subpartDb.md) of this part, as applicable to the affected source.
- (e) Units 1 and 2 (as defined in appendix G of this part) at the Newton Power Station owned or operated by the Central Illinois Public Service Company will be in compliance with [paragraph (a)(2)](#a-2) of this section if Unit 1 and Unit 2 individually comply with [paragraph (a)(2)](#a-2) of this section or if the combined emission rate from Units 1 and 2 does not exceed 470 ng/J (1.1 lb/MMBtu) combined heat input to Units 1 and 2.

## Notes

### Amendments

[60 FR 65415, Dec. 19, 1995, as amended at 74 FR 5077, Jan. 28, 2009]

### Source

Source: 72 FR 32717, June 13, 2007, unless otherwise noted.

### Authority

Authority: 42 U.S.C. 7401 et seq.

### Source

Source: 36 FR 24877, Dec. 23, 1971, unless otherwise noted.

### Amendments

[60 FR 65415, Dec. 19, 1995, as amended at 74 FR 5077, Jan. 28, 2009]