# §60.282. Standard for particulate matter.

- (a) On and after the date on which the performance test required to be conducted by [§ 60.8](/cfr/40/60.8.md) is completed, no owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere:
  - (1) **From any recovery furnace any gases which—**
    - (i) Contain particulate matter in excess of 0.10 g/dscm (0.044 gr/dscf) corrected to 8 percent oxygen.
    - (ii) **Exhibit 35 percent opacity or greater.**
  - (2) From any smelt dissolving tank any gases which contain particulate matter in excess of 0.1 g/kg black liquor solids (dry weight)[0.2 lb/ton black liquor solids (dry weight)].
  - (3) **From any lime kiln any gases which contain particulate matter in excess of—**
    - (i) 0.15 g/dscm (0.066 gr/dscf) corrected to 10 percent oxygen, when gaseous fossil fuel is burned.
    - (ii) 0.30 g/dscm (0.13 gr/dscf) corrected to 10 percent oxygen, when liquid fossil fuel is burned.

## Notes

### Amendments

[43 FR 7572, Feb. 23, 1978, as amended at 65 FR 61758, Oct. 17, 2000]

### Authority

Authority: 42 U.S.C. 7401 et seq.

### Source

Source: 36 FR 24877, Dec. 23, 1971, unless otherwise noted.

### Amendments