# §183.588. Slosh test.


A fuel tank is tested by performing the following procedures in the following order:

- (a) Perform the static pressure test under [§ 183.580](/cfr/33/183.580.md).
- (b) Perform the pressure impulse test under [§ 183.586](/cfr/33/183.586.md).
- (c) **Secure the tank to the platform of a tank rocker assembly.**
- (d) **Fill the tank to one-half capacity with water.**
- (e) **Cap and seal each opening in the tank.**
- (f) Apply 500,000 cycles or rocking motion 15 degrees to each side of the tank centerline at the rate of 15 to 20 cycles a minute. The axis of rotation of the rocker and fuel tank must be perpendicular to the centerline of the tank length at a level six inches or less above or below the tank's bottom.
- (g) Perform the static pressure test under [§ 183.580](/cfr/33/183.580.md).