# §154.570. Lighting.

- (a) Except as provided in [paragraph (c)](#c) of this section, for operations between sunset and sunrise, a facility must have fixed lighting that adequately illuminates:
  - (1) Each transfer connection point on the facility;
  - (2) Each transfer connection point in use on any barge moored at the facility to or from which oil or hazardous material is being transferred;
  - (3) Each transfer operations work area on the facility; and
  - (4) Each transfer operation work area on any barge moored at the facility to or from which oil or hazardous material is being transferred.
- (b) Where the illumination is apparently inadequate, the COTP may require verification by instrument of the levels of illumination. On a horizontal plane 3 feet above the barge deck or walking surface, illumination must measure at least:
  - (1) 5.0 foot candles at transfer connection points; and
  - (2) 1.0 foot candle in transfer operations work areas.
- (c) For small or remote facilities, the COTP may authorize operations with an adequate level of illumination provided by the vessel or by portable means.
- (d) Lighting must be located or shielded so as not to mislead or otherwise interfere with navigation on the adjacent waterways.

## Notes

### Amendments

[CGD 75-124, 45 FR 7172, Jan. 31, 1980, as amended by CGD 86-034, 55 FR 36253, Sept. 4, 1990]

### Authority

Authority: 33 U.S.C. 1321(j)(1)(C), (j)(5), (j)(6), and (m)(2); 46 U.S.C. 70011, 70034; sec. 2, E.O. 12777, 56 FR 54757; Department of Homeland Security Delegation No. 00170.1, Revision No. 01.2. Subpart F is also issued under 33 U.S.C. 2735. Vapor control recovery provisions of Subpart P are also issued under 42 U.S.C. 7511b(f)(2).