# §127.109. Lighting systems.

- (a) The marine transfer area for LNG must have a lighting system and separate emergency lighting.
- (b) All outdoor lighting must be located or shielded so that it is not confused with any aids to navigation and does not interfere with navigation on the adjacent waterways.
- (c) The lighting system must provide an average illumination on a horizontal plane one meter (3.3 feet) above the deck that is—
  - (1) 54 lux (five foot-candles) at any loading flange; and
  - (2) 11 lux (one foot-candle) at each work area.
- (d) The emergency lighting must provide lighting for the operation of the—
  - (1) Emergency shutdown system;
  - (2) Communications equipment; and
  - (3) **Firefighting equipment.**