# §75.1434. Retirement criteria.


Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs:

- (a) **The number of broken wires within a rope lay length, excluding filler wires, exceeds either—**
  - (1) Five percent of the total number of wires; or
  - (2) Fifteen percent of the total number of wires within any strand;
- (b) On a regular lay rope, more than one broken wire in the valley between strands in one rope lay length;
- (c) A loss of more than one-third of the original diameter of the outer wires;
- (d) Rope deterioration from corrosion;
- (e) Distortion of the rope structure;
- (f) Heat damage from any source;
- (g) Diameter reduction due to wear that exceeds six percent of the baseline diameter measurement; or
- (h) **Loss of more than ten percent of rope strength as determined by nondestructive testing.**