# §7.307. Static pressure test.

- (a) **Test procedure.**
  - (1) The enclosure shall be internally pressurized to a minimum of 150 psig and the pressure maintained for a minimum of 10 seconds.
  - (2) Following the pressure hold, the pressure shall be removed and the pressurizing agent removed from the enclosure.
- (b) **Acceptable performance.**
  - (1) The enclosure during pressurization shall not exhibit—
    - (i) Leakage through welds or casting; or
    - (ii) **Rupture of any part that affects the explosion-proof integrity of the enclosure.**
  - (2) The enclosure following removal of the pressurizing agent shall not exhibit—
    - (i) Visible cracks in welds;
    - (ii) Permanent deformation exceeding 0.040 inches per linear foot; or
    - (iii) Clearances, in excess of those specified in this subpart, along accessible flame-arresting paths, following any necessary retightening of fastenings.