# §7.102. Exhaust gas cooling efficiency test.

- (a) **Test procedures.**
  - (1) Follow the procedures specified in [§ 7.101(a)](/cfr/30/7.101.md?p=a).
  - (2) Install a temperature measuring device to measure the exhaust gas temperature at discharge from the exhaust conditioner. The temperature measuring device shall be accurate to ±4 °F (±2 °C).
  - (3) Determine the exhaust gas temperature at discharge from the exhaust conditioner before the exhaust gas is diluted with air.
- (b) **Acceptable performance.**
  - (1) The exhaust gas temperature at discharge from a wet exhaust conditioner before the exhaust gas is diluted with air shall not exceed 170 °F (76 °C).
  - (2) The exhaust gas temperature at discharge from a dry exhaust conditioner before the gas is diluted with air shall not exceed 302 °F (150 °C).