# §57.22221. Overcast and undercast construction (I-A, II-A, III, and V-A mines).


Overcasts and undercasts shall be—

- (a) Of substantial construction;
- (b)
  - (1) Constructed of noncombustible materials; or
  - (2) Where constructed of combustible materials, the outside surfaces shall be coated with at least one inch of construction plaster containing perlite and gypsum; at least one inch of expanded vermiculite, Portland cement and limestone; or other coatings with equivalent fire resistance;
- (c) **Kept clear of obstructions.**