# §1910.244. Other portable tools and equipment.

- (a) **Jacks—**
  - (1) **Loading and marking.**
    - (i) The operator shall make sure that the jack used has a rating sufficient to lift and sustain the load.
    - (ii) The rated load shall be legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means.
  - (2) **Operation and maintenance.**
    - (i) In the absence of a firm foundation, the base of the jack shall be blocked. If there is a possibility of slippage of the cap, a block shall be placed in between the cap and the load.
    - (ii) The operator shall watch the stop indicator, which shall be kept clean, in order to determine the limit of travel. The indicated limit shall not be overrun.
    - (iii) After the load has been raised, it shall be cribbed, blocked, or otherwise secured at once.
    - (iv) Hydraulic jacks exposed to freezing temperatures shall be supplied with an adequate antifreeze liquid.
    - (v) All jacks shall be properly lubricated at regular intervals.
    - (vi) Each jack shall be thoroughly inspected at times which depend upon the service conditions. Inspections shall be not less frequent than the following:

      (a) For constant or intermittent use at one locality, once every 6 months,

      (b) For jacks sent out of shop for special work, when sent out and when returned,

      (c) For a jack subjected to abnormal load or shock, immediately before and immediately thereafter.

    - (vii) Repair or replacement parts shall be examined for possible defects.
    - (viii) Jacks which are out of order shall be tagged accordingly, and shall not be used until repairs are made.
- (b) **Abrasive blast cleaning nozzles.** The blast cleaning nozzles shall be equipped with an operating valve which must be held open manually. A support shall be provided on which the nozzle may be mounted when it is not in use.

## Notes

### Amendments

[39 FR 23502, June 27, 1974, as amended at 49 FR 5323, Feb. 10, 1984]

### Authority

Authority: Sections 4, 6, and 8 of the Occupational Safety and Health Act of 1970 (29 U.S.C. 653, 655, 657); Secretary of Labor's Order No. 12-71 (36 FR 8754), 8-76 (41 FR 25059), 9-83 (48 FR 35736), 1-90 (55 FR 9033), or 5-2007 (72 FR 31159), as applicable; 29 CFR part 1911. Section 1910.243 also issued under 29 CFR part 1910.

### Authority

Authority: 33 U.S.C. 941; 29 U.S.C. 653, 655, 657; Secretary of Labor's Order No. 12-71 (36 FR 8754); 8-76 (41 FR 25059), 9-83 (48 FR 35736), 1-90 (55 FR 9033), 6-96 (62 FR 111), 3-2000 (65 FR 50017), 5-2002 (67 FR 65008), 5-2007 (72 FR 31160), 4-2010 (75 FR 55355), 1-2012 (77 FR 3912), 08-2020 (85 FR 58393), or 07-2025 (90 FR 27878); 29 CFR part 1911; and 5 U.S.C. 553, as applicable.

### Source

Source: 39 FR 23502, June 27, 1974, unless otherwise noted.

### Source

Source: 39 FR 23502, June 27, 1974, unless otherwise noted. Redesignated at 40 FR 23072, May 28, 1975.

### Amendments

[39 FR 23502, June 27, 1974, as amended at 49 FR 5323, Feb. 10, 1984]