# §29.1105. Induction system screens.


If induction system screens are used—

- (a) Each screen must be upstream of the carburetor;
- (b) No screen may be in any part of the induction system that is the only passage through which air can reach the engine, unless it can be deiced by heated air;
- (c) No screen may be deiced by alcohol alone; and
- (d) It must be impossible for fuel to strike any screen.

## Notes

### Authority

Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701-44702, 44704.

### Source

Source: Docket No. 5084, 29 FR 16150, Dec. 3, 1964, unless otherwise noted.