# §25.1731. Powerplant and APU fire detector system: EWIS.

- (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant.
- (b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless:
  - (1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or
  - (2) **Each zone involved is simultaneously protected by the same detector and extinguishing system.**
- (c) EWIS that are part of each fire or overheat detector system in a fire zone must meet the requirements of [§ 25.1203](/cfr/14/25.1203.md).