kind: "section"
citation: "14 C.F.R. § 25.1041"
title: "14"
number: "25.1041"
heading: "General."
url: "https://uscodex.org/cfr/14/25.1041"
---

# §25.1041. General.


The powerplant and auxiliary power unit cooling provisions must be able to maintain the temperatures of powerplant components, engine fluids, and auxiliary power unit components and fluids within the temperature limits established for these components and fluids, under ground, water, and flight operating conditions, and after normal engine or auxiliary power unit shutdown, or both.


## Notes

### Amendments

[Amdt. 25-38, 41 FR 55467, Dec. 20, 1976]

### Authority

Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701, 44702 and 44704; Pub. L. 115-254, 132 Stat 3281 (49 U.S.C. 44903 note).

### Source

Source: Docket No. 5066, 29 FR 18291, Dec. 24, 1964, unless otherwise noted.

### Amendments

[Amdt. 25-38, 41 FR 55467, Dec. 20, 1976]