# §835.1101. Control of material and equipment.

- (a) Except as provided in paragraphs [(b)](#b) and [(c)](#c) of this section, material and equipment in contamination areas, high contamination areas, and airborne radioactivity areas shall not be released to a controlled area if:
  - (1) Removable surface contamination levels on accessible surfaces exceed the removable surface contamination values specified in appendix D of this part; or
  - (2) Prior use suggests that the removable surface contamination levels on inaccessible surfaces are likely to exceed the removable surface contamination values specified in appendix D of this part.
- (b) Material and equipment exceeding the removable surface contamination values specified in appendix D of this part may be conditionally released for movement on-site from one radiological area for immediate placement in another radiological area only if appropriate monitoring is performed and appropriate controls for the movement are established and exercised.
- (c) Material and equipment with fixed contamination levels that exceed the total contamination values specified in appendix D of this part may be released for use in controlled areas outside of radiological areas only under the following conditions:
  - (1) Removable surface contamination levels are below the removable surface contamination values specified in appendix D of this part; and
  - (2) The material or equipment is routinely monitored and clearly marked or labeled to alert personnel of the contaminated status.

## Notes

### Source

Source: 63 FR 59686, Nov. 4, 1998, unless otherwise noted.

### Authority

Authority: 42 U.S.C. 2201, 7191; 50 U.S.C. 2410.

### Source

Source: 58 FR 65485, Dec. 14, 1993, unless otherwise noted.